A quality controller fixes a temperature logger to a carton of durian before it is loaded into a reefer
REEFER DATA EVIDENCE · PRACTICAL GUIDE

Durian container temperature loggers: place sensors so the evidence holds up

How to place temperature loggers in durian containers so they link to real lots and positions, separate setpoint, supply and return air and product temperature, and come with calibration and an evidence pack.

By · Updated · Reading time 13 min
EXECUTIVE TAKEAWAYS

Primary keyword: durian container temperature logger

  • Short answer: a temperature logger used as evidence must show which device was with which lot, in which position, when it started recording, which time standard it used and how its raw data was handed over. One logger with no position plan and no chain of custody gives you a single line on a chart, not proof of the condition of the whole load.
  • Setpoint is the container’s instruction, supply air is the air delivered, return air is the air flowing back to the unit, and a product logger reads the area around where it is fixed. These four layers can differ, so read them together with sensor position, airflow, defrost, off-power and transport events.
  • No single number of loggers, spacing or excursion threshold suits every shipment. Set them from the product specification, load plan, risk points, distance, buyer conditions and equipment capability, and approve the plan before the container is closed.
01

Start from the question you must prove, not from the number of loggers

Before choosing devices, state what you need to confirm: for example, temperature around the product from packhouse to consignee, differences between the front, middle and back of the container, or events relevant to delivery acceptance and claims. Only then design the measuring points, frequency and data custodian. A logger measures only its immediate surroundings, so it should never be read automatically as standing for every fruit or every carton.

  • Define the measurand clearly: air around the carton, product surface or internal product temperature.
  • Base the criteria on the product specification and contract revision for the actual shipment.
  • State the decision the data will support: release, investigation, claim or process improvement.
  • Name the data owner and the exception approver before loading starts.
02

Separate setpoint, supply air, return air and the product logger

Hapag-Lloyd explains that supply air is the air delivered into the container and return air is the air that has passed through the cargo and returns to the unit, and that actual temperature can differ from the setpoint because of ambient conditions, product respiration, hot stuffing or blocked airflow. The controller log and the cargo logger are therefore different layers of evidence that must sit on the same timeline.

  • Setpoint: an instruction to the controller, not the product temperature.
  • Supply air: the air conditions the unit delivers into the cargo space.
  • Return air: air that has picked up heat from the cargo, walls and surroundings before returning to the unit.
  • Product logger: the value at its fixing point, not an average for the container.
  • Receiver measurement: readings at door opening and inspection, with their own method, points and time recorded separately.

Defrost can push the return-air line up temporarily

The return-air sensor sits near the evaporator section and may read high during defrost. Check the event log and the timing; don’t open a claim or change the setpoint from a single line on a chart.

No data does not mean off-power

Loss of network signal can interrupt telemetry while the controller keeps recording. Compare power events, the controller log, loggers and milestones before drawing a conclusion.

03

Lock 16 fields in the temperature logger plan

Prepare one plan per container and approve it before stuffing starts. Every logger must be linked to its real position and to the shipment master. If a device is swapped or moved, open an exception; never overwrite the original data.

  • 1 Shipment, booking, container and seal.
  • 2 Product, lot, pallet or carton and quantity loaded.
  • 3 Product specification and revision.
  • 4 Device ID, serial number, model and firmware where relevant.
  • 5 Measuring range, accuracy, resolution and sampling interval.
  • 6 Calibration status, certificate reference and due date.
  • 7 Position by front, middle and back, and by high, middle and low level.
  • 8 Photo or load map showing the position.
  • 9 Activation time and installer.
  • 10 Time zone and clock-sync result.
  • 11 Approved temperature and excursion criteria.
  • 12 How the device is secured without blocking airflow.
  • 13 Chain-of-custody owner at each handover.
  • 14 Download method and raw file format.
  • 15 Retention period, access control and checksum or version.
  • 16 Checker, approver and the plan if a logger is lost or unreadable.
04

Place sensors by risk and build a load map

The number and positions must come from the questions you need to answer and from thermal mapping or verifiable experience. Don’t put every logger by the door because it’s easy to reach, or against walls and air paths by accident. For containers where spatial differences matter, the plan should cover front, middle and back and the levels that are risk points, while keeping the T-floor, red load line and return-air path clear as the load plan requires.

  • Fix loggers to an identifiable cargo unit; never leave devices loose.
  • Avoid direct contact with walls, floor, metal or supply air unless that is the measurand you want.
  • Don’t let cables, devices or cartons block vents or air paths.
  • Take wide and close-up photos with the position code before closing the container.
  • With limited loggers, rank the risk points and record coverage gaps transparently.

There is no universal sensor-count formula

Containers, routes, packaging, density and objectives differ. A fixed number set without qualification can give more confidence than the evidence supports.

05

Activate, sync the clock and hand over with a chain of custody

Data with mismatched times can’t be compared with loading, gate-in, plug-out, vessel and receiving. Before installing, check battery, memory, start mode, sampling interval and clock. Use UTC as the base or state the time zone clearly, then scan the device ID against container, lot and position. At each handover, sender and receiver confirm the status without altering raw timestamps.

  • Take a test reading and confirm the logger is recording before closing the carton or container.
  • Record activation, installation and door-closing times separately.
  • Use QR codes or barcodes to avoid pairing the wrong serial number.
  • Never reuse a logger from another shipment without creating a new history.
  • Name who is responsible for retrieval and download at destination.
06

Calibrate to suit the intended use

In the BIPM vocabulary, metrological traceability links a measurement result to a reference through a documented, unbroken chain of calibrations, each contributing to measurement uncertainty. But being traceable doesn’t automatically make the uncertainty fit for every job. Check the certificate, calibration points, uncertainty, the tolerance used for decisions and the due date together.

  • Set calibration intervals from risk, drift history and external requirements; don’t copy a blanket interval.
  • Review as-found and as-left results where available to assess the impact on earlier shipments.
  • Run reference checks before and after each trip per SOP, but don’t call a verification a calibration if it isn’t one.
  • Quarantine devices that are past due, dropped, water-damaged or read wrong against a reference.
  • Record corrections and uncertainty when they are needed for a pass or fail decision.
07

Read the chart as evidence reconciliation

When you find an excursion, build one timeline from the raw logger data, controller supply and return air, power and defrost, GPS and milestones, door events, ambient conditions and the arrival inspection. Then classify it as a true temperature event, a localised reading, a clock mismatch, a data gap or a device issue. Editing the chart or picking convenient periods without keeping the raw file destroys the credibility of the evidence.

  • Keep the raw CSV or original file with the export timestamp and who downloaded it.
  • Annotate a working copy without changing the original.
  • Compare positions on the same time zone and sampling interval.
  • Separate duration, magnitude and the area affected; don’t conclude from a single peak.
  • Have the QC or cold-chain owner assess the quality impact together with the arrival inspection and product specification.
08

Assemble the evidence pack and an SOP for abnormal data

A good evidence pack lets the buyer, carrier, surveyor and internal team look at the same data set. Start by preserving evidence, place a disposition hold where needed, check the device and context, notify the parties within the SLA, and only then analyse the impact. Avoid assigning blame before reconciliation is complete.

  • The approved temperature logger plan and load map.
  • Device register, calibration certificate and pre-use check.
  • Installation photos, seal and container record and handover log.
  • Raw logger file, controller and event log and carrier telemetry.
  • Loading, gate, vessel and receiving timeline with time zones.
  • Arrival inspection, survey, NCR, CAPA and disposition approver.
09

KPIs and AI that help without replacing the approver

AI can catch clock drift, data gaps, suspiciously flat sensors, positional differences and correlations with power or defrost. But it must preserve raw data, show where each alert came from and let the owner confirm before any hold, release or claim. Judging the impact on quality stays with the authorised person and the approved specification.

  • Logger activated before door close: 100%.
  • Device–container–lot–position linkage: 100%.
  • Calibration valid at time of use: 100%.
  • Raw file retrieval rate.
  • Clock drift and data-gap rate.
  • Excursion response time.
  • Sensor loss or damage rate.
  • False alarms and human overrides, with reasons.
FAQ · Quick answers

Frequently asked questions

Can one temperature logger represent the whole container?

Generally not. A logger reflects the area where it is fixed. Define the purpose, risk points, load map and coverage first; only then can you explain what level of conclusion the data supports.

Are supply air and return air the durian’s temperature?

Not directly. Supply air is the air delivered and return air is the air coming back to the unit after passing through the cargo. Both explain how the container is working, but must be compared with product loggers and actual events.

Should loggers go by the door or in the middle of the container?

Place them according to a risk-based plan, which may need to cover front, middle, back and several levels. No single position suits every job, and accidental contact with walls or air paths should be avoided.

Does a temperature rise during defrost mean the fruit is damaged?

Not yet. The return-air sensor can read high temporarily during defrost. Check the event log, duration, product logger, position and arrival inspection before assessing the impact.

Does traceable calibration mean the device is accurate enough for any specification?

Not always. Check measurement uncertainty, calibration points and range, the job’s tolerance, drift history and status on the day of use together.

Can we keep a screenshot of the chart instead of the raw file?

You shouldn’t. A screenshot lacks metadata and complete data points. Keep the original raw export with device ID, time zone, who downloaded it and version, and use chart images only as explanatory copies.

Read next and put it to work

Durian reefer power interruptions: control every plug-in and off-power eventDurian reefer claims and the evidence packDurian reefer settings: control setpoint, air exchange and humidityDurian reefer load plan: control airflow, weight and spacePre-cooling export durian: remove field heat before loadingDurian cold chain: from temperature logs to exception management

Official sources

Information last checked on 7 September 2026

  1. About Hapag-Lloyd LIVE — ReeferHapag-Lloyd · Checked 7 September 2026
  2. FAQ — Hapag-Lloyd LIVEHapag-Lloyd · Checked 7 September 2026
  3. MSC iReefer FAQsMSC · April 2026 edition; checked 7 September 2026
  4. What is a reefer container: The Comprehensive GuideMSC · 26 August 2025; checked 7 September 2026
  5. Code of Practice for Packaging and Transport of Fresh Fruit and Vegetables (CXC 44-1995)Codex Alimentarius · Checked 7 September 2026
  6. VIM4 — International Vocabulary of Metrology, second committee draftBIPM/JCGM · 31 July 2023; checked 7 September 2026
  7. Recommended Calibration IntervalNIST · Checked 7 September 2026
  8. GS1 Global Traceability StandardGS1 · Checked 7 September 2026