Durian reefer power interruptions: control every plug-in and off-power event
How to keep reefer power continuous for durian from packhouse, truck, depot and terminal to vessel and consignee, with a Power Handover Record, alert SLAs, an evidence pack and human approval.
By the DurianTradeX team · Updated · Reading time 12 minPrimary keyword: durian reefer power interruption
- Short answer: run every reefer as One Container, One Power Chain. Record the plug-out and plug-in time, location, power source, who handed over, who took over, controller status and alarms at every point from packhouse to consignee.
- No data does not always mean off-power. Communication can drop while the unit keeps running, so compare power status, the controller event log, supply and return air, the product logger and transport events before you conclude anything.
- There is no single maximum off-power time that is safe for every shipment. Set the alert SLA from the product specification, fruit condition, starting temperature, packing, ambient conditions and the carrier’s instructions for the actual job.
Control power as a chain, not by reading the chart at destination
A reefer changes power source many times between the packhouse, the truck, the depot, the terminal, the vessel and the destination. The risk sits in each handover, so every point needs an owner and evidence. Don’t wait for an odd temperature chart and then work backwards to find the cause.
- Use container number, seal number, shipment and lot as one reference set along the whole route.
- Record plug-out and plug-in times in one time zone, or state the time zone clearly.
- Capture controller status, alarms and power source before handover and after takeover.
Lock 15 fields in the Power Handover Record
The Power Handover Record should be one standard evidence set per container, so operations, the carrier, the buyer and the claims team all see the same events. Data must come from accountable people and from devices that can be traced.
- Container No.
- Seal No.
- Shipment/booking reference
- Location
- Event type: plug-in or plug-out
- Local timestamp and time zone
- Power source
- Setpoint
- Supply air
- Return air
- Controller status
- Active alarm
- Handed over by
- Taken over by
- Photo, file or event-log reference
Set a risk-based alert SLA
The alert SLA has to be fast enough for the team to check and restore power before the risk grows, but it shouldn’t come from one generic number. The cargo owner and a cold-chain specialist should set thresholds from the product spec and the real route, then review them against past incident data.
- Split alerts into missing telemetry, confirmed off-power, temperature deviation and controller alarm.
- Name L1, L2 and L3 owners and a backup channel when the primary contact doesn’t respond.
- Every override needs a reason, an approver, a time and supporting evidence.
Separate no data from off-power
Missing data on a monitoring platform can come from the network, the communication device or the provider’s system. Don’t automatically conclude that power was lost. Check several sources and keep each system’s original timestamps so you can reconcile them.
- Compare remote monitoring with the controller event log and on-site confirmation.
- Check supply and return air together with the product logger where there is one.
- Log the data gap as an exception until evidence closes it.
Trucks and depots need a real power handover
Haulage and queuing are where the container usually switches from shore power to a genset, or waits for a plug-in at the yard. The plan must say which source covers each leg, who is responsible for fuel and checking the unit, and what the fallback is when equipment or the queue is late.
- Check genset readiness before leaving the loading point when the transport plan requires one.
- Record the ETA to the plug-in point and escalate when it runs past the set time.
- Don’t close the incident until there is evidence that the unit is back to running as instructed.
Investigate alarms by cause, don’t just acknowledge them
An alarm is a signal to check the cause and the impact, not just an item to acknowledge. Closing an alarm must be linked to the fix on site, the status after the fix and the person who confirms the unit is back within the required conditions.
- Separate power alarms, sensor or communication alarms and temperature alarms.
- Keep before-and-after evidence for any event that affects the cold chain.
- Raise a CAPA when an incident repeats at the same handover point or with the same provider.
Build the evidence pack from the first minute
If an event could turn into a dispute or a claim, evidence collected immediately is worth far more than evidence gathered later. Keep original files and key metadata, and keep the link between container, shipment, lot and event.
- Export the event log and monitoring data in a format that keeps timestamps and source.
- Photograph the controller, seal, power point and fruit condition where relevant.
- Record who was notified, when, how they replied and what instruction was given.
Use AI to catch exceptions, not to decide for the people in charge
AI can merge events from several systems, find missing time windows, spot conflicting timestamps and rank incidents by urgency. But concluding the cause or the damage, accepting liability or releasing a shipment should stay under human approval and verifiable evidence.
- Start in shadow mode and measure false positives and false negatives.
- Show source, timestamp and confidence with every recommendation.
- Don’t let AI fill in events or container readings that have no source evidence.
Run a mock incident before the export season
The team should rehearse a power loss, a lost connection, a genset that won’t run and an out-of-hours response. The point is to measure whether alerts reach the people who are really responsible and whether the evidence pack can be built straight away.
- Time each step: detect, acknowledge, verify, recover, close.
- Test backup channels and escalation across organisations.
- Issue a CAPA with an owner and a due date after every drill.
Track KPIs that reflect real continuity
The dashboard should show management how often incidents happen, how fast the team responds, where risk repeats and how good the evidence is. Don’t count alarms alone, because more or fewer alarms doesn’t mean the risk is under control.
- Confirmed off-power events per 100 containers
- Median and 95th percentile detect-to-recover time
- Share of handovers with all 15 fields evidenced
- Repeat incident rate by location, carrier and route
- Share of incidents closed with root cause and CAPA within SLA
Frequently asked questions
Does no data from the tracking system mean the power went off?
Not always. Check power status, the controller event log, telemetry, temperatures and on-site confirmation before concluding, because communication can drop while the container keeps running.
What is the maximum time a reefer can be off power?
There is no single number that suits every shipment. Set the threshold from the product spec, pre-loading condition, packing, ambient temperature, route and the carrier’s instructions for the actual job.
What evidence should we keep when we find an off-power event?
At minimum: container and seal, timestamp and time zone, location, power source, controller and alarms, supply and return air, the product logger where there is one, site photos, the people responsible, notifications and the recovery result.
Can AI make decisions about reefers automatically?
AI is good at spotting exceptions and ranking urgency. Releasing a shipment or concluding cause or liability should need human approval and rest on evidence from the real systems.
Official sources
Information last checked on 5 September 2026
- iReefer remote container monitoringMSC · Checked 5 September 2026
- Captain Peter remote container management servicesMaersk · Checked 5 September 2026
- Hapag-Lloyd LIVE FAQHapag-Lloyd · Checked 5 September 2026
- Shipping glossary and standard terminologyDigital Container Shipping Association · Checked 5 September 2026