A QC officer and a laboratory scientist seal durian samples and record traceability data in a packhouse
FOOD SAFETY · PRACTICAL GUIDE

BY2 and cadmium testing for durian: control every sample up to container release

A guide to controlling BY2 and cadmium testing for durian exported to China, from contamination prevention and sampling to chain of custody and hold–release decisions for each shipment.

By · Updated · Reading time 12 min
EXECUTIVE TAKEAWAYS

Primary keyword: BY2 testing durian China

  • A test result can only support a release when the sample ID links farm, lot, sampler, time, container, seal, laboratory and shipment without gaps.
  • Thailand’s Department of Agriculture said on 12 March 2026 that 14 laboratories were registered with GACC, but a packhouse must check each lab’s status, scope and the latest instructions every time before using it.
  • Never wait for results without a status: lots and shipments stay on quality hold until results are complete, reviewed and approved for release by an authorised person.
01

The short answer: what a BY2 and cadmium testing system needs before a container can be released

A system that works covers far more than sending durian to a lab. It starts with preventing contamination in the orchard and packhouse, sets a sampling plan based on the latest requirements, creates sample IDs linked to farm and lot, keeps the chain of custody intact through collection, sealing, transport and lab receipt, and enforces a quality hold until results are reviewed before the shipment is released. As of 12 March 2026 the Department of Agriculture reported 14 GACC-registered laboratories for export testing, but the number and their status can change, so confirm through official channels and with the lab before use.

  • Prevention: reduce the chance of contamination before sampling.
  • Identity: one sample ID along the whole route.
  • Integrity: sealing and a recorded handover at every step.
  • Decision: hold, review and release, each with a clear owner.
  • Evidence: results and related lots can be found instantly.
02

Prevent before you test: Big Cleaning has to be a control plan

The Department of Agriculture’s Big Cleaning guidance for packhouses covers not using dyes or banned substances in production, replacing equipment at risk of dye contamination, cleaning areas and equipment such as fans, crates, knives, pallets and containers, and using clean water. Turn this into a pre-operation checklist with area, inspector, time, result, photo evidence and corrective action. One clean before the season is not enough: when equipment, people or products change, assess the risk and clean again under your own plan.

  • Keep a list of chemicals and equipment permitted in production areas.
  • Separate cleaning equipment by zone to reduce cross-contamination.
  • Check for residue, dye, dust, water and food-contact surfaces before work starts.
  • Hold or replace equipment whose history is unknown or that cannot be cleaned.
  • Record deviations and CAPA, not just photos of the activity.
03

Design the sampling plan without guessing the criteria

The number of samples, sampling points, tissue tested, compositing method, frequency and how long a result remains valid must follow the latest official orders or manuals, as well as the requirements of the market, the buyer and the accepted laboratory. This guide therefore does not set a fixed number of fruit or lots, because one formula for every season and area may not meet the requirement. Keep a sampling requirement register showing the source, date checked, approver and review date, and separate regulatory, verification and investigation samples clearly.

  • State the product, variety, farm, lot, packing date and shipment the sample represents.
  • Name a qualified sampler, and a witness where needed.
  • Prevent picking only good-looking fruit or convenient spots.
  • Record the reason whenever sampling cannot follow the plan and have QA assess the impact.
  • When an order changes, retire the old form and issue a new revision.
04

Create sample IDs and a chain of custody that can be traced back

Issue the sample ID at the point of collection and never rewrite different numbers on the bag, the submission form and the result file. The ID should link farm ID, inbound lot, date and time of collection, sampler, sampling point, quantity or mass, container, seal, transport conditions, the person handing over, the laboratory and the candidate shipment. Every handover needs a time, sender, receiver and seal condition. If IDs do not match, a seal is broken or transport time or temperature is out of spec, mark it as a sample exception and do not use the result for release automatically.

  • Print labels from the system to avoid copying codes by hand.
  • Photograph samples and seals before they leave the packhouse.
  • Use closed boxes and keep samples apart to prevent cross-contamination.
  • Record dispatch and laboratory receipt timestamps.
  • Never change the farm or lot after results are issued without a revision and an approver.
05

Choose laboratories from an approved lab register

“We’ve used this lab before” is not enough. Keep an approved lab register with the legal entity, location, accreditation number, test scope, methods, recognition status with the relevant authorities, contact, turnaround time, sample acceptance conditions and the date last confirmed. The Department of Agriculture listed 14 GACC-registered laboratories as of 12 March 2026, but that figure does not mean every lab suits every method or every shipment. Check the actual scope and status before sending samples.

  • Confirm status from official sources, not just a quotation.
  • Check that the name and address on the report match the approved register.
  • Qualify a backup lab in advance.
  • Track real turnaround time, the rate of amended reports and sample rejections.
  • Review the register whenever requirements or a lab’s status change.
06

Tie results to quality hold and shipment release

When a sample is created, the system should hold the lot it represents and show which preparation steps may continue while export stays blocked. Receiving a PDF in a chat should never switch the status to passed. The reviewer must confirm sample ID, lab, method and scope, received and reported dates, result, unit, reference criteria, report status and fit with the shipment before approving release. If a shipment combines several farms or lots, keep a coverage matrix that shows which result covers which part, and never use one lot’s result for another without a clear basis in the requirements.

  • Minimum statuses: awaiting sample → in transit → lab received → testing → QA review → passed / failed / invalid.
  • The release rule must check every requirement that applies to the shipment.
  • The maker never approves the release of their own entry.
  • Keep the original report with a hash or version to prevent file swaps.
  • Expired results, or results outside their coverage, must not be reused.
07

When a result is abnormal: hold the scope before looking for the cause

In 2025 the Department of Agriculture ordered more than 60 tonnes of BY2-contaminated durian destroyed and suspended exports from 26 packhouses, a clear lesson that a slow response hurts both the product and the right to export. When a result is failed, suspect, invalid or the data does not match, hold the sample, the lot, any product processed from it and the linked shipments. Assess the scope through equipment, time, shift, supplier and area. Do not simply retest and discard the original result without an investigation. Notifying authorities, keeping, destroying or releasing product must follow the requirements and orders of the competent authority for that case.

  • Open an incident ID and appoint an incident owner.
  • Lock the audit trail of the original result and every status change.
  • Run one step back, one step forward and a mass balance.
  • Keep evidence of cleaning, chemical use, suppliers and relevant CCTV or photos.
  • Close CAPA once effectiveness is confirmed, not when the paperwork is issued.
08

A dashboard and 30-day plan for management

In week one, walk the process from sampling to container release and list your laboratories. In week two, set the sample ID, chain of custody and approved lab register. In week three, set up quality hold and the coverage matrix. In week four, run a mock incident: take one report back to the farm and forward to cartons, container and buyer. Management should see exceptions before averages, because a single sample mismatch can affect an entire shipment. AI can check codes, expiry dates and document mismatches, but interpreting results and approving release needs human review.

  • KPI: sample–lot–shipment linkage completeness = 100%.
  • KPI: sample ID mismatches or broken seals used for release = 0.
  • KPI: shipments released before results are complete = 0.
  • KPI: lab turnaround against cut-off, and containers at risk of missing the vessel.
  • KPI: overdue critical CAPA = 0.
FAQ · Quick answers

Frequently asked questions

Does one BY2 “not detected” sample guarantee the whole lot is safe?

You cannot conclude beyond what the sample covers. Confidence depends on the sampling plan, representativeness, collection method, chain of custody, test method and criteria, so state the coverage of each result clearly and follow the latest official requirements.

How should we choose a lab for BY2 and cadmium testing?

Check recognition status and the scope of test methods through the latest official channels, and confirm the location, accreditation number, sample acceptance conditions and the report that will be issued. Do not choose on price, distance or past use alone.

After Big Cleaning, do we still need testing?

Big Cleaning is a preventive measure that reduces risk; it does not replace testing the product. Sampling still has to follow the current orders, market requirements and shipment conditions.

Can we pack or load while waiting for results?

That depends on the latest requirements and your own risk controls. If preparation may continue, the status must remain quality hold with clear segregation and control, and nothing may be exported until every requirement is met and an authorised person approves.

If a result is abnormal, should we retest immediately?

Hold the affected scope and open an incident first. Any resampling or retesting needs a reason and an approved plan, must not automatically cancel the original result, and should be coordinated with the authorities or specialists as the requirements for that case demand.

How can AI help control durian test results safely?

AI is well suited to catching sample ID mismatches, duplicate files, overdue results or lab status issues, and to summarising shipments still missing results. It should not interpret results legally or approve release without review by a responsible person.

Read next and put it to work

Get a durian packhouse ready for audits and China exportDurian GAP and traceability that works in practiceDocument control for durian exportsGACC Order 280 and Thai durian: what to check after 1 June 2026

Official sources

Information last checked on 13 August 2026

  1. Fruit export quality control for the 2026 season and GACC-registered laboratories (Thai)Department of Agriculture, Thailand · 12 March 2026
  2. Eastern durian Big Cleaning Day and BY2 contamination prevention (Thai)Department of Agriculture, Thailand · 24 February 2025
  3. Destruction of BY2-contaminated durian and suspension of packhouse exports (Thai)Department of Agriculture, Thailand · 5 February 2025
  4. GACC audit of Thai fruit production sites, packhouses and laboratories (Thai)Department of Agriculture, Thailand · 23 June 2025
  5. Sampling of GAP durian for cadmium surveillance in 2026 (Thai)Office of Agricultural Research and Development Region 4, Department of Agriculture · 17 June 2026
All articlesTry the platform